*Produktuaren xehetasun gehiago lortzeko, begiratu beheko informazioa edo jarri gurekin harremanetan zuzenean
ESKAERAREN INFORMAZIOAOEM | |
Fabrikatzailea | OEM pieza zenbakia |
AMC | PR-E600-1011N (Mikroapar sentsorea), PR-E600-1013N (Mikroapar sentsorea) |
Konfederatua | 2311 |
Covidien > Nellcor | D25 |
Draeger | 4534434 |
Envitec | DA-2411-1, DA-2211-1, DA-2271-1 |
GE Osasun-laguntza > Marquette | 2023217-001 |
Mediaid | CST034-2121 (45 cm) |
Philips | M1131A, 989803128531 |
Bateragarritasuna: | |
Fabrikatzailea | Modeloa |
Artema SandW | Diaskopioa |
Bionet | BM3, BM3 Plus |
Bionika | BPM-200 |
Biosys | BPM-200, SENTRY |
Covidien > Nellcor | N-10, N-100, N-180, N-190, N-20, N-200, N-30, N-3000, N-390, N-395, N-6000, NPB-190, NPB-195, NPB-290, NPB-295, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-40, NPB-4000, NPB-75, Symphony N-3000 |
Datex Ohmeda | enGuard CM5 |
Draeger | Cicero, Infinity Delta XL, Infinity Gamma, Infinity Gamma XL, Infinity Kappa, Infinity Vista, Narkomed, Narkomed 4, Narkomed 6400, SC 6000, SC 7000, SC 8000, SC 9000XL, Vitalert 1000 |
Edan | H100B |
Fukuda Denshi | Dynascope DS-5100E, Dynascope DS-5300W |
GE Healthcare > Korometria | 118, 120, 129, 188, 510, 511, 556 |
GE Healthcare > Critikon > Dinamap | 1000, 3000, 9710, 9720, Compact, Dinamap Select, M-NSAT Moduluak, MPS, Oxyshuttle, Plus, Pro 1000, Pro 300, Pro 300/400, Pro 400, Pro Seriea, ProCare, SMU, SMV, SOLAR Seriea, TRAM Modular x50SL Seriea |
GE Osasun-laguntza > Marquette | Cardioserv, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Dash Seriea, Eagle 1000, Eagle 4000, Eagle Seriea, Hellige Eagle, Hellige SMK, PDM Modulua, Procare B40, Solar 8000, Solar 8000M, Tram 451, i/9500 |
Urrezko bidea | UT4000Apro, UT4000C, UT4000E, UT4000F, UT4000F Pro, UT6000A, Vet 420A |
Huntleigh | SC1000 |
Infinitioa | Infitron II |
Invivo | 4500 Plus, 4500 Plus 3, Escort 100 OPT11A, Escort 300A, Escort II OPT30, M12, M12 (Nellcor SpO₂), Millennia, Millennia 4500 Plus 2, Omega 1445, Omni-Trak TVS, Prism (Nellcor SpO₂), Sat Scout |
Ivy Biomedikoa | 405A, 405D, 405P, 405T, Vital-Guard 450 CN |
Lumeon | Eskuko oximetroa |
Mennen | Envoy, Horizon XL (Nellcor SpO₂), MR 1300, MR 1300 Mercury 1200, Mercury 1200 |
Mindray > Datu-esparrua | Accutorr Plus, Accutorr V, DPM Estazio Zentrala, DPM1, DPM2, DPM3, DPM4, DPM5, DPM6, DPM7, Duo, Expert, PM-50, PM-60, PM-60Vet, Passport, Passport 2, Passport V, Passport XG, Spectrum, Trio, VS 800, VS 900 |
Nihon Kohden | BSM-1102 Life Scope EC, BSM-2300, BSM-2304 iPro (Life Scope i), BSM-4100, BSM-4102 Procyon LT (Life Scope P), BSM-4104 Procyon (Life Scope P), BSM-4104A, BSM-4112 Procyon LT (Life Scope P), BSM-4114 Procyon (Life Scope P), BSM-4114A, BSM-5100, BSM-9510 Life Scope M (Nellcor SpO₂), OGS-2000 PocketCare (Nellcor SpO₂) |
Omron > Colin | BP-306, BP-508, BP-808, BP-88, BP-88S, Press-Mate |
PaceTech | Vitalmax 800 Seriea (Nellcor SpO₂ beltza) |
Philips | 78352C, 78354C, 78834C, 862108, 862231, 862439, 862474, 862478, 863063, 863069, 863073, 863077, 863266, C1, FM20, FM30, FM40, FM50, M1020A, M1020B, M1025B, M1205A, M1350B, M1350C, M1722A, M1722A/B, M1722B, M1732A, M1732A/B, M1732B, M2475B, M2600A, M2601A, M2703A, M2704A, M2705A, M3000A, M3001A, M3001A A01, M3001A A01C06, M3001A A01C12, M3… Ikusi gehiago |
Schiller | Argus CM8, Argus TM-7 |
Siemens | Sirecust 630, Sirecust 700, Sirem SpO₂ modulua |
Smiths Medical > BCI | 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, Advisor, Autocorr, Mini Torr, Mini Torr Plus |
Espazio-laborategiak | 90351-0/6, 90465 (Nellcor SpO₂), 90466 (Nellcor SpO₂), 90467 (Nellcor SpO₂), 90489 (Nellcor SpO₂), 90496 / 90369 / 90367 SpO₂, 90367 Ultraview (Nell) 90651A-08, IM77 |
Stryker > Medtronic > Fisio Kontrola | Lifepak 12 |
Suntech | modelo guztiak, NIBP 247B barne |
Teramax | 1000 |
Welch Allyn | Atlas (Nellcor SpO₂), Micropaq (Nellcor SpO₂), Propaq 106-EL, Propaq 202-EL, Propaq 204-EL, Propaq 206-EL, Propaq CS (Nellcor SpO₂), Spot Vital Signs, Vital Signs (ez-Oxi-Max) |
Ezaugarri teknikoak: | |
Kategoria | Botatzeko SpO₂ sentsoreak |
Araudiaren betetzea | FDA, CE, ISO 80601-2-61:2011, ISO10993-1, 5, 10:2003E, TUV, RoHS betetzen du |
Konektore distala | 7 pineko D-Sub konektore arra |
SpO₂ Teknologia | Nellcor OxiSmart |
Pazientearen tamaina | Heldua |
Kablearen luzera osoa (ft) | 3 oin (0,9 m) |
Kablearen kolorea | zuria |
Kablearen diametroa | 3,2 mm |
Kablearen materiala | PVC |
Sentsorearen materiala | Garraiatu |
Latexik gabekoa | Bai |
Ontziratze mota | kutxa |
Ontziratze unitatea | 24 pieza |
Paketearen pisua | Esterilizazioa eskuragarri |
Bermea | E/G |
Esterila | Eman daiteke. |