Factory Free sample Disposable Edwards Pressure Transducer - Hand-held Multi-Gas Analyzer – Med-link


Product Detail

Product Tags

Related Video

Feedback (2)

Our staff are usually in the spirit of "continuous improvement and excellence", and while using the top-quality high-quality items, favorable value and superior after-sales services, we try to acquire each and every customer's belief for Blood Oxygen Probe, Ecg Lead Wire Manufacturers, High Temperature Sensor Probe, "Making the Products of High Quality" is the eternal goal of our company. We make unremitting efforts to realize the goal of "We Will Always Keep in Pace with the Time".
Factory Free sample Disposable Edwards Pressure Transducer - Hand-held Multi-Gas Analyzer – Med-link Detail:

Product features 

1. This device is an anesthesia agent analyzer used to measure EtCO2, FiCO2, RR, EtN2O, FiN2O, EtAA, FiAA. 

2. This monitor is suitable for all kinds of animals and may be applied in general ward, including, but not limited to ICU, CCU or ambulance and so forth.

Specifications

1. Main Unit’s Environment Requirement

Working:          Temperature: 5℃~50℃; 

                        Relative humindity: 0~95%;          

                        Atmosphere Pressure: 70.0KPa~106.0KPa

Storage:          Temperature: 0℃~70℃; 

                       Relative humindity: 0~95%;

                       Atmosphere Pressure: 22.0KPa~120.0KPa 

2. Power Specification

Input Voltage:       12V DC

Input Current:       2.0 A    

3. Physical Specification

Main Unit

Weight:               0.65Kg

Dimension:         192mm x 106mm x 44mm

4. Hardware Specification

TFT Screen

Type:                   Colorful TFT LCD

Dimension:          5.0 inch

Battery                          

Quantity:             4

Model:                Rechargeable lithium battery

Voltage:             3.7 V

Capacity:           2200mAh

Working time:    10 hours

Recharging time:  4 Hours

LED                             

Patient Alarm Indicator: Two colors: Yellow and Red

Sound Indicator           

Loudspeaker:         Play alarm voices

Interfaces                     

Power:                    12VDC power socket x 1

USB:                       MINI USB socket x 1

5. Measurement Specification

Principle:                 NDIR single beam optics

Sampling Rate:       90mL/min, ±10mL/min

Initialization Time:   Waveform displaying in 20 seconds

Range                           

CO2:                0~99 mmHg, 0~13 %

N2O:                0~100 VOL%

ISO:                 0~6VOL%

ENF:                0~6VOL%

SEV:                0~8VOL%

RR:                 2~150 bpm

Resolution                   

CO2:               0~40 mmHg    ±2 mmHg

                       40 ~99 mmHg  ±5% of reading

N2O:               0~100VOL% 

                       ±(2.0 vol% +5% of reading)

ISO:               0~6VOL%   

                      ±(0.3 vol% +2% of reading)

ENF:               0~6VOL%   

                       ±(0.3 vol% +2% of reading)

SEV:               0~8VOL%   

                       ±(0.3 vol% +2% of reading)

RR:                ±1 bpm

Apnea Alarm Time:    20~60s

6. MAC value define 

l 1.0MAC: under an atmospheric pressure condition, give a person or animal skin stimulation, 50% of people or animals not body dynamic response or escape reflection occurs, the inhalation anesthetics in alveolar concentration. 

l To achieve 95% of people don't respond to stimuli, the MAC value should reach to 1.3. 

l When MAC value is 0.4,most patients will wake up.

Anaesthetic agents

Enflurane:           1.68

Isoflurane:              1.16

Sevflurane:              1.71

Halothane:           0.75

N2O:                   100%

Notice             Desflurane’s MAC1.0 values differ with age

Age:              18-30   MAC1.0  7.25%

Age:              31-65   MAC1.0  6.0%

 


Product detail pictures:

Factory Free sample Disposable Edwards Pressure Transducer - Hand-held Multi-Gas Analyzer – Med-link detail pictures


Related Product Guide:
Leaked images supposedly show Fitbit’s next ‘mass appeal’ smartwatch | Neonatal Spo2 Sensor
Fitbit Versa review: Better than the Ionic? | Fetal Monitoring Probe

We are also focusing on enhancing the things administration and QC program in order that we could keep fantastic advantage within the fiercely-competitive enterprise for Factory Free sample Disposable Edwards Pressure Transducer - Hand-held Multi-Gas Analyzer – Med-link, The product will supply to all over the world, such as: Turkmenistan, Hungary, Florence, Our company has already had a lot of top factories and professional technology teams in China, offering the best products, techniques and services to worldwide customers. Honesty is our principle, professional operation is our work, service is our goal, and customers' satisfaction is our future!
  • A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Elizabeth from Hamburg - 2015.02.12 14:52
    Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Doris from Malta - 2016.01.28 18:53

    Related Products