Factory made hot-sale Clip Lead Wire 3-lead Ecg Cable - Hand-held Multi-Gas Analyzer – Med-link
Factory made hot-sale Clip Lead Wire 3-lead Ecg Cable - Hand-held Multi-Gas Analyzer – Med-link Detail:
Product features
1. This device is an anesthesia agent analyzer used to measure EtCO2, FiCO2, RR, EtN2O, FiN2O, EtAA, FiAA.
2. This monitor is suitable for all kinds of animals and may be applied in general ward, including, but not limited to ICU, CCU or ambulance and so forth.
Specifications
1. Main Unit’s Environment Requirement
Working: Temperature: 5℃~50℃;
Relative humindity: 0~95%;
Atmosphere Pressure: 70.0KPa~106.0KPa
Storage: Temperature: 0℃~70℃;
Relative humindity: 0~95%;
Atmosphere Pressure: 22.0KPa~120.0KPa
2. Power Specification
Input Voltage: 12V DC
Input Current: 2.0 A
3. Physical Specification
Main Unit
Weight: 0.65Kg
Dimension: 192mm x 106mm x 44mm
4. Hardware Specification
TFT Screen
Type: Colorful TFT LCD
Dimension: 5.0 inch
Battery
Quantity: 4
Model: Rechargeable lithium battery
Voltage: 3.7 V
Capacity: 2200mAh
Working time: 10 hours
Recharging time: 4 Hours
LED
Patient Alarm Indicator: Two colors: Yellow and Red
Sound Indicator
Loudspeaker: Play alarm voices
Interfaces
Power: 12VDC power socket x 1
USB: MINI USB socket x 1
5. Measurement Specification
Principle: NDIR single beam optics
Sampling Rate: 90mL/min, ±10mL/min
Initialization Time: Waveform displaying in 20 seconds
Range
CO2: 0~99 mmHg, 0~13 %
N2O: 0~100 VOL%
ISO: 0~6VOL%
ENF: 0~6VOL%
SEV: 0~8VOL%
RR: 2~150 bpm
Resolution
CO2: 0~40 mmHg ±2 mmHg
40 ~99 mmHg ±5% of reading
N2O: 0~100VOL%
±(2.0 vol% +5% of reading)
ISO: 0~6VOL%
±(0.3 vol% +2% of reading)
ENF: 0~6VOL%
±(0.3 vol% +2% of reading)
SEV: 0~8VOL%
±(0.3 vol% +2% of reading)
RR: ±1 bpm
Apnea Alarm Time: 20~60s
6. MAC value define
l 1.0MAC: under an atmospheric pressure condition, give a person or animal skin stimulation, 50% of people or animals not body dynamic response or escape reflection occurs, the inhalation anesthetics in alveolar concentration.
l To achieve 95% of people don't respond to stimuli, the MAC value should reach to 1.3.
l When MAC value is 0.4,most patients will wake up.
Anaesthetic agents
Enflurane: 1.68
Isoflurane: 1.16
Sevflurane: 1.71
Halothane: 0.75
N2O: 100%
Notice Desflurane’s MAC1.0 values differ with age
Age: 18-30 MAC1.0 7.25%
Age: 31-65 MAC1.0 6.0%
Product detail pictures:
Related Product Guide:
마시모, PVi®의 성능을 평가한 새로운 연구 결과 발표… 중환자실에서 기계적으로 산소를 공급받은 환자의 수액 반응성 예측변수 측정 | Temperature Sensor Probe
How to Make Recycling Smart and Safe | Spo2 Monitor
We have now probably the most innovative production equipment, experienced and qualified engineers and workers, regarded high quality control systems and also a friendly expert income team pre/after-sales support for Factory made hot-sale Clip Lead Wire 3-lead Ecg Cable - Hand-held Multi-Gas Analyzer – Med-link, The product will supply to all over the world, such as: Oman, Algeria, Cologne, We are trying our best to make more customers happy and satisfied. we sincerely hope to establish a good long-term business relationship with your esteemed company thought this opportunity,based on equal, mutual beneficial and win win business from now till the future.
By Bernice from Moldova - 2016.03.28 16:34
We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
By Queena from America - 2015.10.31 10:02