"Over 20 Years of Professional Medical Cable Manufacturer in china"

Good Quality Water Level Sensor Probe – Philips/HP Compatible Direct-Connect SpO2 Sensor – Med-link

*For more product details, check out the information below or contact us directly

ORDER INFORMATION

Product Pictures

MED-LINK  REF NO.

Compatible Brand

Compatible Models No.

Description (Name,   Length,   Plug,   Compatible)

 S0015B-L

S0015B-L

Philips/HP

 

78352C,   78354C,

78834C,   M1020A,

M1025B,   M1025A,

M1350B,   M1772A/B,

M1732A/B,   M2475B

M3,   M4,   MP20,   MP30,   MP40,   MP50,   MP70,   MP80,   VM4,   VM6,   VM8

 

Adult finger clip,   3M

 S0015D-L

S0015D-L

Adult silicone soft,   3M

 重复性长线血氧探头S0015I-L S0015I-L Neonate wrap sensor (detachable),3M 
 重复性长线血氧探头S0015G-L S0015G-L  Adult ear clip sensor,   3M
 重复性长线血氧探头S0003E-L S0003E-L

78352C,   78354C,

78834C,   M1020A,

M1025B,   M1025A,

M1350B,   M1772A/B,

M1732A/B,   M2475B

Infant silicone,   3M
 重复性长线血氧探头S0003D-L S0003D-L Adult silicone soft,   3M
 重复性长线血氧探头S0003B-L S0003B-L Adult finger clip,   3M

Packing specification:24 / boxes

* Statement: All the registered trademarks, brand names, models and so on shown in the above contents are owned by the original owner or the original manufacturer. This article is only for illustrating the compatibility of Mei Lian products. It has no other intention! All the above information is for reference only. Do not use it as a guide for medical institutions or related units. Otherwise, any consequences will not be related to our company.

Hot Tags:

NOTE:

1. The products are neither manufactured nor authorized by the original equipment manufacturer. Compatibility is based on publicly available technical specifications and may vary depending on the equipment model and configuration. Users are advised to verify compatibility independently. For a list of compatible equipment, please contact our customer service team.
2. The website may reference third-party companies and brands that are not affiliated with us in any way. Product images are for illustrative purposes only and may differ from the actual items (e.g., differences in connector appearance or color). In the event of any discrepancies, the actual product shall prevail.

Related Products

Factory For Ecg 300g Digital Three Channel Ecg –  Holter Recorder ECG Patient Cable and Lead Wires – Med-link

Factory For Ecg 300g Digital Three Channel Ecg ...

Learn more
Bottom price Ibp Cable –  ESU pencil and Connecting Cable for electrosurgery – Med-link

Bottom price Ibp Cable – ESU pencil and ...

Learn more
Factory Supply Diascope G2 Patient Monitor –  Instrument Connector and Socket – Med-link

Factory Supply Diascope G2 Patient Monitor R...

Learn more
100% Original Nibp Tubes –  HyLink SpO2 Sensor – Med-link

100% Original Nibp Tubes – HyLink SpO2 S...

Learn more
Best quality Ep System Electromyography –  Disposable Adult Bi-spectral Index Sensor – Med-link

Best quality Ep System Electromyography –...

Learn more
Factory making Ecg-ekg Banana Connector Adapter Cable –  ETC02 Sensor Connector Series – Med-link

Factory making Ecg-ekg Banana Connector Adapter...

Learn more