New Fashion Design for Nihon Kohden Adult Spo2 Sensor - EKG Multi-Link Cable and Lead Wires – Med-link
New Fashion Design for Nihon Kohden Adult Spo2 Sensor - EKG Multi-Link Cable and Lead Wires – Med-link Detail:
Instrument Connectors:A variety of 15 pin D-subminiature connector and round type solutions are available in either metal or plastic connectors, overmolded housings and straight or angled flex-reliefs. Connectors are surrounded by insert molded flex-reliefs to protect terminations and extend product life.
Trunk Cables:The multi-link an 2 meter (80 inch) trunk cable Shielded, low noise cable minimizes microphonic noise and electrical nterference. Flexreliefs at the connector and cable yoke provide added durability and reduce conductor breakage. The cable is available in AHA or IEC nomenclature and color coded patient terminations. Lot numbers are included to indicate quipment compatibility and product traceability.
Patient end termination:Lead wires can be terminated to a variety of patient connectors to mate with adapters or industry standard electrode attachments. Shielded lead wires are jacketed in TPU and have color coded flex reliefs. Lead wires can accommodate 4.7 k, 10k or 20k ohm resistors (snap, grabber, banana and straight pin only).
Adapted to the electrocardiogram machines of Fukuda,Hellige,GE-Marquette,GE-Medical,Mindray,Spacelabs,GEMS,Philips,CONMED,Mortara.
Image | Model | Compatible Brand: | Item description | Package Type |
VT047BNI | Mortara 250C | 10-Ld Set patient leads, 4 x limb lead (120cm), 6 x chest leads (80cm), no Resistance, 2P plug, IEC, Banana | 1pcs/bag | |
VE008SNA | Hellige , GE-Marquette; suitable for all MultiLink-Plug | 10-Ld Set patient leads, 4 x limb lead (130cm), 6 x chest leads (70cm), no Resistance, VS-2P plug, AHA (AAMI), Snap | 1pcs/bag | |
VT047BNA | Mortara 250C | EKG Lead wires, 10-Ld Set , 4 x limb lead (120cm), 6 x chest leads (80cm); no Resistance, 2P plug, Banana, AHA, 0.08 KG, TPU, Cool Grey | 1pc/bag | |
EQ056-5AI | Drager Siemens ; Multimed-Pot system fur serie SC 6000, SC 6002XL, SC 7000, SC 9000, Art. Nr.3368391 (8.2ft) Art. Nr. 5950196 (4.9ft) ; | SC9000XL Multi-link Cable, 5LD, 8.2ft, AHA/IEC, 1KΩ resistance, 0.341 KG, TPU, Cool Grey, Original model No. : 3368391; fit for Euro style LeadWires | 1pc/bag | |
VX018BNA | PHILIPS Use with Philips Instrument M1700A M1701A M1702A;TRIM II, Trim 1, 2, 3 | AHA (AAMI), Banana, 0.198 KG,TPU, Cool Grey, Original model No. : M1713B | 1pc/bag | |
VF008-15 | GEMS MAC 5000 CAM14 | ext-cable, 15ft, (450cm). 0.2KG, TPU, Cool Grey, | 1pc/bag | |
VE008A51 | Hellige GE-Marquette; For GE MAC 1100/1200/1200ST,CardioSmart, CardioSys, MAC5000, MAC 5000ST, CASE,CASE 8000,Systems with CAM 14 Acquisition Module or with Cable Accepting,CAM 14 Leadwires | Leadwire,CAM/Universal, 51in.(130cm),0.091 KG, TPU, Cool Grey, Original model No. : E9006PM | 4pcs/pk | |
VE008A40 | Hellige GE-Marquette; For GE MAC 1100/1200/1200ST,CardioSmart, CardioSys, MAC5000, MAC 5000ST, CASE,CASE 8000,Systems with CAM 14 Acquisition Module or with Cable Accepting,CAM 14 Leadwires | Leadwire,CAM/Universal, 40in.(102cm),102cm, 0.113 KG, TPU, Cool Grey, Original model No. : E9006PK | 6pcs/pk | |
VE006-BAI | For GE Eagle, Solar, Dash , Tram, MAC-Lab Cath Lab System, Datex-Ohmeda S/5 FM, Original P/N: (AAMI: E9002ZH, 416035-001) (IEC: E9002ZJ, 416035-002) | Multi-Link 12-Ld ECG cable, L=2.2m, Rectangle 11p>VS 10L Yoke, AAMI/IEC , 1kΩ Res. 0.213 KG, TPU, Cool Grey | 1pc/bag | |
EE051S5A | GE-Medica; Holter Multi-Link Leadwire Sets – For GE SEER MC Holter Recorder For GE Eagle, Solar, Dash Monitors, Tram, MAC-Lab Cath Lab System, Datex-Ohmeda S/5 FM | Multi-Link Ldwr Set, 5Ld, 51 in. , L=130cm, AHA (AAMI), Snap, 0.128 KG, Cool Grey, TPU, Original model No. : E9008KC | 1pc/bag | |
VJ032-EAI | Fukuda | 12-Lead ECG Trunk Cable,12pin>>2p*10 Euro Yoke,L=2.2m, AAMI/IEC,20kΩ Res.+discharge,Fit Euro type leadwires | - |
Product detail pictures:
Related Product Guide:
Monteris Medical Announces FDA Clearance of Laser Probe with Fiber Optic Controlled Cooling for Use with the NeuroBlate System | Neonatal Spo2 Sensor
GE Healthcare Integrates Covidien NellcorTM SpO2 with OxiMaxTM Technology and SatSeconds Alarm Management System into Giraffe® and Panda® Infant Warmers | Neonatal Spo2 Sensor
We provide fantastic energy in top quality and advancement,merchandising,gross sales and marketing and operation for New Fashion Design for Nihon Kohden Adult Spo2 Sensor - EKG Multi-Link Cable and Lead Wires – Med-link, The product will supply to all over the world, such as: Bolivia, venezuela, Toronto, Our staffs are adhering to the "Integrity-based and Interactive Development" spirit, and the tenet of "First-class Quality with Excellent Service". According to the needs of every customer, we give customized & personalised services to help customers achieve their goals successfully. Welcome clients from home and abroad to call and inquire!
By Christine from Japan - 2015.11.04 10:32
The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
By Ellen from Uzbekistan - 2016.09.16 13:44